Product Description
UHC's range of magnetic level gauges offer clear indication of liquid level in any chamber configuration required to suit process connections. Standard chamber designs or customized chamber configurations can be built on short delivery times to suit customer requirements. Standard options include switches, reed chain transmitters, magnetostrictive transmitters or insulation for cryogenic applications. Exotic chamber materials or economic 'mini' chamber versions, particularly for refrigeration applications, can be produce on order.
Floats UHC Floats are specifically calibrated to match the conditions of the vessel. The density, operating pressure and temperature are taken into account, ensuring that the inferred level is accurate and repeatable.
Floats material: SUS304, SUS316, PTFE, PP, and Titanium.
Anticorrosive material: such as stainless steel SUS 304 or SUS316L, Teflon PTFE, polypropylene (PP), FRP and advanced tech. application such as X-ray detection, cold-rolling broaching weld, all ensure that the product can be adapted to any demand at site. Additional blow off valve can be added onto the bottom sealing type of the tube when necessary.
Your application is unique, All U-ideal instruments are custom-made based on your requirements.
U-ideal mounting stylesNo matter what your application, we can design and manufacture a magnetic level indicator to fit. Above are our standard mounting styles, but if none of these meet your needs we will come up with the best solution based on your requirements.
NOTE: Style "4" is for through process piping only. Other connections shown are examples of typical process connections and need to be specified.
Typical pictures of magnetic level indicators
Model Selection Table
Basic selection of magnetic level indicator please refer to the following steps:
Remark: Manufactured customized is available for this product.
The magnetic level indicator can be made to Sections if gauge is longer than 3m to make suitable for delivery.
UHC's range of magnetic level gauges offer clear indication of liquid level in any chamber configuration required to suit process connections. Standard chamber designs or customized chamber configurations can be built on short delivery times to suit customer requirements. Standard options include switches, reed chain transmitters, magnetostrictive transmitters or insulation for cryogenic applications. Exotic chamber materials or economic 'mini' chamber versions, particularly for refrigeration applications, can be produce on order.
- Easy to install, no extra piping required in most applications
- Magnetic level gauge Visual level indication up to 30m, sections made suit for delivery. Magnetostrictive level indicator can reach 30m measure range with cable insertion.
- Ideal for high-temperature, high-pressure and corrosive applications.
- Magnetostrictive and radar transmitter options for non-invasive and/or redundant level control.
- Available with HART, 4~20mA, and level switches.
Float Cage Material | SS304, SS316, PTFE, PP, PVC, PVDF |
Max. Centre to Centre Distance | 6000 mm, greater lengths on request |
Connecting Flanges | According to DIN or ANSI B16.5 |
Temperature of Liquid |
450ºC (Max.) for SS, 80ºC (Max.) for PVDF 60ºC (Max.) for PVC, 50ºC (Max.) for PP |
Specific Gravity | Min. 0.45 |
Scale | Graduated in cm, Aluminium or SS304 |
Measuring Accuracy | +/- 5 mm |
Floats UHC Floats are specifically calibrated to match the conditions of the vessel. The density, operating pressure and temperature are taken into account, ensuring that the inferred level is accurate and repeatable.
Floats material: SUS304, SUS316, PTFE, PP, and Titanium.
Anticorrosive material: such as stainless steel SUS 304 or SUS316L, Teflon PTFE, polypropylene (PP), FRP and advanced tech. application such as X-ray detection, cold-rolling broaching weld, all ensure that the product can be adapted to any demand at site. Additional blow off valve can be added onto the bottom sealing type of the tube when necessary.
Your application is unique, All U-ideal instruments are custom-made based on your requirements.
U-ideal mounting stylesNo matter what your application, we can design and manufacture a magnetic level indicator to fit. Above are our standard mounting styles, but if none of these meet your needs we will come up with the best solution based on your requirements.
NOTE: Style "4" is for through process piping only. Other connections shown are examples of typical process connections and need to be specified.
Typical pictures of magnetic level indicators
Model Selection Table
Basic selection of magnetic level indicator please refer to the following steps:
UHC- | C | Side mounted; | |||||||||
D | Top mounted | ||||||||||
O | Other | ||||||||||
Signal | Y | Standard transmitter 4~20mA current signal (Resolution: 20mm/10mm/5mm); | |||||||||
Y3 | Magneticostrictive transmitter 4~20mA | ||||||||||
H | Hart; | ||||||||||
A | Switch and number; | ||||||||||
L | transmitter with LCD | ||||||||||
No signal output | |||||||||||
Indicator type | O | Ordinary pannel | |||||||||
S | Sealed bargraph | ||||||||||
L | Red/Green flaps with LED lamp | ||||||||||
Structure | S | Steam tracing | |||||||||
E | Electric heating | ||||||||||
F | Defrost | ||||||||||
Valve | D | Drain valve or drain plug | |||||||||
DV | Drain valve and Vent valve or plug | ||||||||||
N | No valve | ||||||||||
Working temperature | A | Ambient temperature (0~40ºC) | |||||||||
M | -20~200ºC | ||||||||||
H | High temperature (<400ºC) | ||||||||||
L | If easy frozen | ||||||||||
Material | SS304 | 0Cr18Ni9 | |||||||||
SS316L | 022Cr17Ni12Mo2 | ||||||||||
SS321 | 0Cr18Ni10Ti | ||||||||||
PP | PP (Polypropylene),PVC,PVDF | ||||||||||
PTFE | stainless steel lined with PTFE | ||||||||||
Explosion-proof | S | Safety environment | |||||||||
E | Explostion-proof ExdII BT4 | ||||||||||
I | intrinsic safety ExibII CT4 | ||||||||||
Measure range | Unit: mm | ||||||||||
Fluid density | g/cm3 | ||||||||||
working pressure | Unit: MPa | ||||||||||
Flange size, rate and standard | ANSI | DIN | JIS | ||||||||
Example: UHC-C-YA-O-D-M-SS304-S-500-0.8-1-DIN DN25 PN16 |
The magnetic level indicator can be made to Sections if gauge is longer than 3m to make suitable for delivery.